Section 6
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
No power to unit |
External power source OFF |
Turn On |
Start-Stop switch OFF or defective |
Check |
|
Circuit breaker OFF or tripped |
Check |
|
Loss of control power |
Circuit breaker OFF or defective |
Check |
Control transformer defective |
Check |
|
Fuse (F3A / F3B) blown |
Check |
|
Start-Stop switch OFF or defective |
Check |
|
Component(s) not operating |
Evaporator fan motor internal protector open |
|
Gas Cooler fan motor internal protector open |
||
Compressor internal protector open |
||
High Pressure Switch (HPS) open |
||
Heat Termination Thermostat (HTT) open |
Replace |
|
Current sensor malfunction |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Container |
Hot load |
Normal |
Box insulation defective or air leak |
Repair |
|
Refrigeration system |
Refrigerant shortage |
|
Evaporator coil covered with ice |
||
Evaporator coil plugged with debris |
||
Evaporator coil has air bypass around it |
Check |
|
Controller set too low |
Reset |
|
Coil dirty |
||
Current limit (Cd32) set to wrong value |
||
Economizer Solenoid Valve (ESV) malfunction |
||
Electronic Expansion Valve (EEV) |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Refrigeration system |
Pressures abnormal |
|
Temperatures abnormal |
||
Currents abnormal |
||
Controller malfunction |
||
Evaporator fan or motor defective |
||
Electronic Expansion Valve (EEV) |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
No operation of any kind |
Start-Stop switch OFF or defective |
Check |
Circuit breaker OFF or defective |
Check |
|
External power source OFF |
ON |
|
No control power |
Circuit breaker or fuse defective |
Replace |
Control Transformer defective |
Replace |
|
Evaporator fan internal motor protector open |
||
Heat relay defective |
Check |
|
Heat Termination Thermostat (HTT) open |
||
Unit will not heat or has insufficient heat |
Heater(s) defective |
|
Heater contactor or coil defective |
Replace |
|
Evaporator fan motor(s) defective |
||
Evaporator fan motor contactor defective |
Replace |
|
Controller malfunction |
||
Wiring defective |
Replace |
|
Terminal connections loose |
Tighten |
|
Line voltage low |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Unit fails to stop heating |
Controller improperly set |
Reset |
Controller malfunction |
||
Heat Termination Thermostat (HTT) remains closed along with the heat relay |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Will not initiate defrost automatically |
Defrost timer malfunction (Cd27) |
|
Terminal connections loose |
Tighten |
|
Wiring defective |
Replace |
|
Defrost Temperature Sensor (DTS) defective or Heat Termination Thermostat (HTT) open |
Replace |
|
Heater contactor or coil defective |
Replace |
|
Will not initiate defrost manually |
Manual defrost switch defective |
Replace |
Keypad defective |
Replace |
|
Defrost Temperature Sensor (DTS) open |
Replace |
|
Initiates but relay DR drops out |
Low line voltage |
|
Initiates but does not defrost |
Heater contactor or coil defective |
Replace |
Heater(s) burned out |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
High discharge pressure |
Gas Cooler coil dirty |
|
Gas Cooler fan rotating backwards |
||
Gas Cooler fan inoperative |
||
Refrigerant overcharge or non-condensibles |
||
High Pressure Expansion Valve (HPXV) control malfunction |
Replace |
|
Low suction pressure |
Software incorrect and/or controller configuration incorrect |
Check |
Suction Pressure Transducer (SPT) failed |
Replace |
|
Evaporator air flow not present or restricted |
||
Electronic Expansion Valve (EEV) control malfunction |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Compressor |
Mounting bolts loose |
Tighten / Replace |
Liquid slugging |
||
Gas Cooler or Evaporator Fan |
Bent, loose or striking venturi |
Check |
Motor bearings worn |
||
Motor shaft bent |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Will not control |
Software incorrect and/or controller configuration incorrect |
Check |
Sensor defective |
||
Wiring defective |
Check |
|
Refrigerant charge low |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Evaporator coil blocked |
Coil has frost |
|
Coil dirty |
||
No or partial evaporator air flow |
Evaporator fan motor internal protector open |
|
Evaporator fan motor(s) defective |
||
Evaporator fan(s) loose or defective |
||
Evaporator fan contactor defective |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Low suction pressure |
Software incorrect and/or controller configuration incorrect. |
Check |
Suction Pressure Transducer (SPT) failed |
Replace |
|
Evaporator air flow not present or restricted |
||
Evaporator coil has excessive frost |
||
Electronic Expansion Valve (EEV) control malfunction |
||
Evaporator Temperature Sensor (ETS) loose or insufficiently clamped |
Replace |
|
High suction pressure with low superheat |
Valve contains foreign material |
|
Suction Pressure Transducer (SPT) failed |
Replace |
|
Electronic Expansion Valve (EEV) control malfunction |
Replace |
|
Liquid slugging in compressor |
Suction Pressure Transducer (SPT) failed |
Replace |
Electronic Expansion Valve (EEV) failed |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
High discharge pressure |
High Pressure Expansion Valve (HPXV) coil not seated properly, loose, or not fully engaged. |
|
Software incorrect or controller configuration incorrect |
Check |
|
Discharge Pressure Transducer (DPT) failed |
Replace |
|
Filter drier restriction |
||
Gas Cooler Temperature Sensor (GCTS) loose or insufficiently clamped |
Check |
|
Gas cooler coil dirty |
||
Gas cooler fan rotating backwards |
||
Gas cooler fan inoperative |
||
HPXV control malfunction |
Replace |
|
HPXV failed |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
High discharge temperature |
Gas cooler coil dirty |
|
Gas cooler fan rotating backwards |
||
Gas cooler fan inoperative |
||
Refrigerant overcharge or non-condensibles |
||
Electronic Expansion Valve (EEV) control malfunction |
Replace |
|
Suction Pressure Transducer (SPT) failed |
Replace |
|
Discharge Temperature Sensor drifting high |
Replace |
|
Sensor loose or insufficiently clamped |
Replace |
|
Electronic Solenoid Valve (ESV) coil not fully engaged |
||
ESV or ESV coil malfunction |
Replace |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Unit reads abnormal currents |
Current sensor wiring |
Check |
Component is defective |
Check current draw / Replace as needed. |
Condition |
Possible Cause |
Remedy / Reference |
---|---|---|
Fuse F1 or F2 Blown |
Electronic Expansion Valve (EEV) drive module wires were grounded. |
Check EEV drive module by unplugging it, replacing the fuse(s) and turning the unit back on. |